Eaton Flexi Bi-Wire & Conventional Fire Alarm Control Panel
Code: FPS004/001
from
INC VAT
Code: FPS004/001
The Eaton Bi-Wire Flexi Fire Alarm Panel delivers a versatile solution by supporting both two-wire and traditional conventional setups within a single system.
Each zone can be set up independently to work with either wiring method, giving you the freedom to combine standard and two-wire devices throughout the site. This makes the panel a strong choice for new installations as well as upgrades where existing cables or detectors need to be reused.
Its interface matches the familiar layout of Eaton’s 8-zone conventional panel, helping installers complete configuration and servicing with ease.
Compliant with EN54 Parts 2 and 4, and designed in line with BS 5839 guidance, the Bi-Wire Flexi provides reliable fire detection which aligns with current UK fire safety standards.
Whether you want to save time with two-wire circuits or need to incorporate specialised conventional devices, the panel adjusts to the requirements of the project.
Eaton Flexi Bi-Wire & Conventional Fire Alarm Control Panel | ||
Supports conventional & two-wire detection on the same system | Each zone is configurable independently | Compatible with a wide range of devices |
Easy-to-use interface for fast setup and servicing | Ideal for mixed-system upgrades and phased retrofits | Certified to EN54 Parts 2 & 4 |
Meets BS 5839 fire safety recommendations | Reliable fire detection that complies with UK standards | Allows you to mix conventional and two-wire devices across your install |
Specification | 2 Zone Panel | 4 Zone Panel | 8 Zone Panel |
|---|---|---|---|
Reference | EFW2Z-FLEXI | EFW4Z-FLEXI | EFW8Z-FLEXI |
Description | 2 zone panel | 4 zone panel | 8 zone panel |
Input Voltage Range | 18.75–30 V DC | ||
Max Current Drawn From Battery | 2.7 A | ||
Number of Zones | 2 | 4 | 8 |
Devices Per Zone | Bi-Wire: Max 32 Bi-Wire Detectors & MCPs incl. sounders (≤200mA) Conventional: Max 32 Conv Devices & MCPs | ||
Max Loading Per Zone | 200 mA | ||
Standby Zone Voltage | Vmin 19V DC, Vmax 23V DC | ||
Alarm Zone Voltage | Vmin 31V DC, Vmax 33V DC | ||
Zone Fuse Protection | 250 mA PTC | ||
End of Line Termination | Bi-Wire: EOLM-3 Conventional: 4k7Ω or EOLM-1/3 | ||
Sounder Circuits | 2 circuits (Bi-Wire or Conv) | 2 circuits (Bi-Wire or Conv) | 2 circuits in Bi-Wire, 4 circuits in Conv |
Sounder Fuse Protection | 250 mA PTC | ||
Sounder EOL Termination | 6k8Ω | ||
Relay Outputs | Volt-free SPDT (30V DC, 1A) | ||
Relay Output Fuse | 500 mA PTC | ||
Aux Output Voltage | 11.6–13.0 V | ||
Aux Output Current (max) | 500 mA | ||
Aux Output Fuse | 500 mA PTC | ||
Class Change Input | Open = Normal, Short = All Sounders | ||
Repeater Port | RS485 | ||
Node ID | 1 | ||
Operating Temp | -5°C to +40°C | ||
Humidity | 93% ±3% non-condensing | ||
IP Rating | IP30 | ||
Weight (excl. batteries) | 2.25 kg | ||
Material | PC ABS Front and Rear | ||
Cable Access | 29x 20mm drill positions | ||
Cable Type | FT120 (Fitted/Optional) | ||
Loop Cable | 2-core (1.5–2.5 mm²), 500m max | ||
Standards | EN54-2 & -4, BS5839 pt1 | ||
The Eaton Bi-Wire Flexi Fire Alarm Panel delivers a versatile solution by supporting both two-wire and traditional conventional setups within a single system.
Each zone can be set up independently to work with either wiring method, giving you the freedom to combine standard and two-wire devices throughout the site. This makes the panel a strong choice for new installations as well as upgrades where existing cables or detectors need to be reused.
Its interface matches the familiar layout of Eaton’s 8-zone conventional panel, helping installers complete configuration and servicing with ease.
Compliant with EN54 Parts 2 and 4, and designed in line with BS 5839 guidance, the Bi-Wire Flexi provides reliable fire detection which aligns with current UK fire safety standards.
Whether you want to save time with two-wire circuits or need to incorporate specialised conventional devices, the panel adjusts to the requirements of the project.
Eaton Flexi Bi-Wire & Conventional Fire Alarm Control Panel | ||
Supports conventional & two-wire detection on the same system | Each zone is configurable independently | Compatible with a wide range of devices |
Easy-to-use interface for fast setup and servicing | Ideal for mixed-system upgrades and phased retrofits | Certified to EN54 Parts 2 & 4 |
Meets BS 5839 fire safety recommendations | Reliable fire detection that complies with UK standards | Allows you to mix conventional and two-wire devices across your install |
Specification | 2 Zone Panel | 4 Zone Panel | 8 Zone Panel |
|---|---|---|---|
Reference | EFW2Z-FLEXI | EFW4Z-FLEXI | EFW8Z-FLEXI |
Description | 2 zone panel | 4 zone panel | 8 zone panel |
Input Voltage Range | 18.75–30 V DC | ||
Max Current Drawn From Battery | 2.7 A | ||
Number of Zones | 2 | 4 | 8 |
Devices Per Zone | Bi-Wire: Max 32 Bi-Wire Detectors & MCPs incl. sounders (≤200mA) Conventional: Max 32 Conv Devices & MCPs | ||
Max Loading Per Zone | 200 mA | ||
Standby Zone Voltage | Vmin 19V DC, Vmax 23V DC | ||
Alarm Zone Voltage | Vmin 31V DC, Vmax 33V DC | ||
Zone Fuse Protection | 250 mA PTC | ||
End of Line Termination | Bi-Wire: EOLM-3 Conventional: 4k7Ω or EOLM-1/3 | ||
Sounder Circuits | 2 circuits (Bi-Wire or Conv) | 2 circuits (Bi-Wire or Conv) | 2 circuits in Bi-Wire, 4 circuits in Conv |
Sounder Fuse Protection | 250 mA PTC | ||
Sounder EOL Termination | 6k8Ω | ||
Relay Outputs | Volt-free SPDT (30V DC, 1A) | ||
Relay Output Fuse | 500 mA PTC | ||
Aux Output Voltage | 11.6–13.0 V | ||
Aux Output Current (max) | 500 mA | ||
Aux Output Fuse | 500 mA PTC | ||
Class Change Input | Open = Normal, Short = All Sounders | ||
Repeater Port | RS485 | ||
Node ID | 1 | ||
Operating Temp | -5°C to +40°C | ||
Humidity | 93% ±3% non-condensing | ||
IP Rating | IP30 | ||
Weight (excl. batteries) | 2.25 kg | ||
Material | PC ABS Front and Rear | ||
Cable Access | 29x 20mm drill positions | ||
Cable Type | FT120 (Fitted/Optional) | ||
Loop Cable | 2-core (1.5–2.5 mm²), 500m max | ||
Standards | EN54-2 & -4, BS5839 pt1 | ||
ex vat
ex vat
ex vat
ex vat
ex vat
ex vat
ex vat
ex vat
Fire Protection Shop specialise in the supply of high-quality fire extinguishers. There are many different classifications of fire and so our products include a variety of different extinguisher types. For example, we offer water or foam fire extinguishers for solid combustibles and carbon dioxide fire extinguishers for flammable liquid or electrical fires. Each extinguishing agent comes with its benefits. Typically, water extinguishers are cheaper, produce a cooling effect and prevent reignition once the fire has been extinguished. Carbon dioxide extinguishers are clean agents, they leave no residue, are suitable for electrical fires and are often used on liquid fires which include petrol, oil or other solvents.
In addition to our extinguishers, we offer a range of fire safety products to both domestic and commercial premises. This includes the supply of fire blankets, extinguisher stands, smoke alarms, first aid kits and much more. Our entire range is sourced from reputable brand manufacturers at competitive prices. Also, all of our products carry a full warranty and guarantee and are supplied with relevant fixings where applicable.
So, for fire extinguishers, alarms and all your other fire safety needs, trust Fire Protection Shop to give you the quality, expertise and service you require.
We use cookies to enhance your site experience. Choose your preferences below.