Purchase Your Fire Extinguisher Servicing Online Now - Available Across The Country
PFOA & PFOS WILL BE BANNED JULY 2025, THIS DOESN'T INCLUDE PFAS EXTINGUISHERS
1 item added to basket
C-TEC BF560-24 24V 1.5A EN54-4 Power Supply Unit
Code: CTEC001/020
INC VAT
Code: CTEC001/020
Ideal for powering beam detectors, auto-dial communicators, aspirating smoke detectors, auto-open vent systems, auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.
Certified to EN54-4/A2 by the LPCB and VdS (AFNOR pending).
A powerful switch mode/digital hybrid PSU that can be customised* to suit your exact requirements
Plastic cover on PSU PCB guards against touching live parts.
Includes a single-pole volt free changeover relay that switches for any fault condition.
Multiple indicators – supply present, general fault, fault type & aux. equipment fault.
Two selectable battery charge currents.
Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
Mains fail simulation mode.
Improved on-board temperature sensor with optional remote sensor.
Electronic functions comply with EN50131-6 grades 1-4 for security applications.
BF560-24/E caged & BF560-24/C PCB-only versions available.
Approvals/certifications | Certified to EN54-4/A2 by the LPCB & VdS. AFNOR approval pending. |
---|---|
Application/operation | A boxed Mains to regulated DC power supply providing 1.5A @ 24V DC. It includes a single pole volt-free changeover relay that switches for any fault condition. User customisable via a BF423 Configu |
Mains supply | 230V 50/60Hz. |
Mains rated current | 400mA r.m.s. |
Total output current limited to | 1.5A (Max. output current). |
Output | I max.a: 1.3A or 0.8A selectable. A load greater than I max.a will temporarily reduce batt. charging. I.max.b: 1.5A, charging turned off via CONN6. Output is also customisable via a BF423 Configura |
Battery charge capacity | 2Ah up to 12Ah (battery charged to 80% capacity in 24 hrs). Max. battery size/type determined by cabinet size is 3.2Ah VRLA). Output is customisable via a BF423 Configurator to suit different manuf |
Max battery size and type | 2 x 12V 3.2Ah VRLA (min. size is 2 x 12V 2Ah). |
Indicators | 3 external – Supply Present (Green); General Fault (Amber); Auxiliary Fault (Amber) and 2 internal – Hazardous Voltages Present (Red) and PSU Status (Amber). |
Connections | Mains Input (CONN1); Supply Output (CONN3); Battery Input (CONN3); Fault Relay (CONN4); Charge Off Input (CONN5). Battery Charge Current Link (PLK1); Battery Monitoring On/Off Link (PLK2); High Tem |
Expansion connections | A remote thermistor can be connected via PL3 terminals. |
Product dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
Construction & finish | PVC lid and base; RAL7035 textured. |
IP Rating | IP30 (designed for indoor use only). |
Weight | 1.55kg (without batteries). |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95%. |
Notes | *Parameters configurable via a BF423 configurator are: Float voltage temp. compensation; Batt. charge rate (mA); Batt. impedance; Configurable Input/Output settings. Note: Changing the PSU's parame |
Ideal for powering beam detectors, auto-dial communicators, aspirating smoke detectors, auto-open vent systems, auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.
Certified to EN54-4/A2 by the LPCB and VdS (AFNOR pending).
A powerful switch mode/digital hybrid PSU that can be customised* to suit your exact requirements
Plastic cover on PSU PCB guards against touching live parts.
Includes a single-pole volt free changeover relay that switches for any fault condition.
Multiple indicators – supply present, general fault, fault type & aux. equipment fault.
Two selectable battery charge currents.
Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
Mains fail simulation mode.
Improved on-board temperature sensor with optional remote sensor.
Electronic functions comply with EN50131-6 grades 1-4 for security applications.
BF560-24/E caged & BF560-24/C PCB-only versions available.
Approvals/certifications | Certified to EN54-4/A2 by the LPCB & VdS. AFNOR approval pending. |
---|---|
Application/operation | A boxed Mains to regulated DC power supply providing 1.5A @ 24V DC. It includes a single pole volt-free changeover relay that switches for any fault condition. User customisable via a BF423 Configu |
Mains supply | 230V 50/60Hz. |
Mains rated current | 400mA r.m.s. |
Total output current limited to | 1.5A (Max. output current). |
Output | I max.a: 1.3A or 0.8A selectable. A load greater than I max.a will temporarily reduce batt. charging. I.max.b: 1.5A, charging turned off via CONN6. Output is also customisable via a BF423 Configura |
Battery charge capacity | 2Ah up to 12Ah (battery charged to 80% capacity in 24 hrs). Max. battery size/type determined by cabinet size is 3.2Ah VRLA). Output is customisable via a BF423 Configurator to suit different manuf |
Max battery size and type | 2 x 12V 3.2Ah VRLA (min. size is 2 x 12V 2Ah). |
Indicators | 3 external – Supply Present (Green); General Fault (Amber); Auxiliary Fault (Amber) and 2 internal – Hazardous Voltages Present (Red) and PSU Status (Amber). |
Connections | Mains Input (CONN1); Supply Output (CONN3); Battery Input (CONN3); Fault Relay (CONN4); Charge Off Input (CONN5). Battery Charge Current Link (PLK1); Battery Monitoring On/Off Link (PLK2); High Tem |
Expansion connections | A remote thermistor can be connected via PL3 terminals. |
Product dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
Construction & finish | PVC lid and base; RAL7035 textured. |
IP Rating | IP30 (designed for indoor use only). |
Weight | 1.55kg (without batteries). |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95%. |
Notes | *Parameters configurable via a BF423 configurator are: Float voltage temp. compensation; Batt. charge rate (mA); Batt. impedance; Configurable Input/Output settings. Note: Changing the PSU's parame |
SK001/022
ex vat
FAC001/056
ex vat
8812
ex vat
FAEKIT2
ex vat
SB001/004
ex vat
Fire Protection Shop specialise in the supply of high-quality fire extinguishers. There are many different classifications of fire and so our products include a variety of different extinguisher types. For example, we offer water or foam fire extinguishers for solid combustibles and carbon dioxide fire extinguishers for flammable liquid or electrical fires. Each extinguishing agent comes with its benefits. Typically, water extinguishers are cheaper, produce a cooling effect and prevent reignition once the fire has been extinguished. Carbon dioxide extinguishers are clean agents, they leave no residue, are suitable for electrical fires and are often used on liquid fires which include petrol, oil or other solvents.
In addition to our extinguishers, we offer a range of fire safety products to both domestic and commercial premises. This includes the supply of fire blankets, extinguisher stands, smoke alarms, first aid kits and much more. Our entire range is sourced from reputable brand manufacturers at competitive prices. Also, all of our products carry a full warranty and guarantee and are supplied with relevant fixings where applicable.
So, for fire extinguishers, alarms and all your other fire safety needs, trust Fire Protection Shop to give you the quality, expertise and service you require.
We use cookies to enhance your site experience. Choose your preferences below.